Reference
The full standard
All 54 requirements grouped by pillar. Filter by tier or pillar; tap any card to slide in the full detail.
Tier
Cumulative through this tier — requirements.
Pillar
requirements in this pillar.
Pillar 1
Energy & Climate Resilience (12)
-
Air Leakage Between Attached Units
Required from Certified Attached housing only Stepped · 4 tiersReduce air movement between attached housing units. Stringency tightens at higher tiers (ACH50 thresholds differ for new construction vs. renovation).
-
Climate Risk Assessment
Required from Certified Counts toward Resilience, Nature-friendly, WalkabilityDetermine the project's future climate risks using a climate-resource tool. Document and mitigate identified risks (stringency rises by tier).
-
Majority LED Lighting
Required from Certified Counts toward GHI Zero Energy Certified, GHI Zero Energy Ready Certified, Reduced Electromagnetic Frequency (EMF)A majority of fixtures use LED lamps.
-
Home Energy Performance
Required from Silver Stepped · 3 tiers Counts toward GHI Zero Energy Certified, GHI Zero Carbon Certified, GHI Zero Energy Ready Certified, Foam-freeDOE Home Energy Score (existing) or modeled annual energy use (new construction). Alternative tools include HERS, PHPP, WUFI Passive, BeOpt, and 90.1.
-
Properly Sized Cooling Equipment
Required from SilverCooling equipment sized per ACCA Manual J 8th Edition (or equivalent load calculation).
-
Refrigerant Charge Verification
Required from SilverRefrigerant charge test completed on all AC and heat-pump equipment.
-
All-Electric Cooking
Required from Gold Counts toward GHI Zero Energy Certified, GHI Zero Carbon Certified, GHI Zero Energy Ready Certified, Electrified LivingCooking appliances are all-electric.
-
All-Electric Dryer
Required from Gold Counts toward GHI Zero Energy Certified, GHI Zero Carbon Certified, GHI Zero Energy Ready Certified, Electrified Living, Peak Load ShaverClothes dryer is all-electric (heat-pump dryer preferred).
-
All-Electric or Dual-Fuel Heating
Required from Gold Counts toward GHI Zero Energy Certified, GHI Zero Carbon Certified, GHI Zero Energy Ready Certified, Electrified Living, Peak Load ShaverSpace heating is all-electric or dual-fuel/hybrid. (At Platinum, all-electric only.)
-
All-Electric or Solar Water Heating
Required from Gold Counts toward GHI Zero Energy Certified, GHI Zero Carbon Certified, GHI Zero Energy Ready Certified, Electrified Living, Peak Load ShaverWater heating is all-electric (heat pump preferred) or solar.
-
Solar- and EV-Ready Electrical Service
Required from Platinum Counts toward GHI Zero Energy Certified, GHI Zero Carbon Certified, GHI Zero Energy Ready Certified, Resilience, Walkability, Peak Load Shaver200-amp breaker box with capacity to add future solar PV and electric-vehicle chargers.
-
Time-of-Use / Peak-Load Appliances
Required from Platinum Counts toward Resilience, Peak Load ShaverMajor appliances support time-of-use scheduling and/or peak-load avoidance.
Pillar 2
Indoor Air Quality & Health (16)
-
Bathroom Exhaust Ventilation
Required from Certified Counts toward Healthier Home (Clean Living)Bath fans exhaust to the outdoors (verified with a toilet-paper test). Silver and above must also test to ≥ 50 CFM per bathroom.
-
Carbon Monoxide Detectors
Required from CertifiedHardwired CO detectors installed on every floor and near any fireplace.
-
Carbon Monoxide Testing of Combustion Appliances
Required from CertifiedCO leak test performed on all combustion-based appliances. Repair or replace any appliance that fails.
-
Fireplace Safety
Required from CertifiedIf a combustion fireplace exists: seal, vent, provide makeup air, and install a CO detector. (At Platinum, no combustion fireplaces indoors — electric only.)
-
Gas Leak Inspection
Required from CertifiedAll gas appliances and piping inspected for leaks. No leaks permitted; repair or replace before certification.
-
HVAC Filter Rating
Required from Certified Stepped · 4 tiers Counts toward Healthier Home (Clean Living)Minimum MERV rating for filters on ducted heating/cooling systems.
-
Radon Testing and Mitigation
Required from Certified Counts toward Healthier Home (Clean Living)Test for radon; no levels above PCL 4 permitted. Install a passive or active mitigation system if needed. All new construction and all EPA Zone 1 homes require a system.
-
Range Hood Tested at 100 CFM (or Electric Stove)
Required from Certified Counts toward Healthier Home (Clean Living)Either install an electric stove, or have a range hood that is tested to vent at least 100 CFM to the outdoors.
-
Kitchen Ventilation
Required from Silver Counts toward Healthier Home (Clean Living)Kitchen has proper ventilation via range hood, outdoor air system, or air-quality monitor. (At Platinum, the range hood must detect PM2.5 and activate automatically.)
-
Sealed/Vented New Gas Appliances
Required from SilverAny new gas appliances are sealed-combustion / vented to the outdoors — or the project goes all-electric.
-
Whole-House Fresh Air Supply
Required from Silver Counts toward Healthier Home (Clean Living)A whole-house mechanical fresh-air supply system is provided.
-
Balanced Fresh-Air System
Required from Gold Counts toward Healthier Home (Clean Living)A balanced (supply + exhaust) fresh-air system is installed and tested.
-
Indoor Air Quality Sensor
Required from Gold Counts toward Healthier Home (Clean Living), Reduced Electromagnetic Frequency (EMF)RESET-certified air-quality sensor installed in the main living area or ducts. (At Platinum, sensor measures CO₂, TVOC, humidity, temp, and PM2.5.)
-
No Indoor Combustion Fireplace
Required from PlatinumNo combustion fireplaces present indoors. Electric fireplaces permitted.
-
Ventilation with Heat/Energy Recovery or Smart Controls
Required from Platinum Counts toward Healthier Home (Clean Living)Ventilation includes energy-recovery / heat-recovery (ERV/HRV) or smart-control features.
-
Whole-Home Humidity Control
Required from Platinum Counts toward Healthier Home (Clean Living)Whole-home dehumidification / humidification provided where appropriate by climate (target 40–50°F dewpoint).
Pillar 3
Water Efficiency & Management (11)
-
Bathroom Aerator Flow Rate
Required from Certified Stepped · 4 tiers Counts toward Zero Water Capable, Home Water ScoreAverage measured flow rate of all bathroom faucet aerators.
-
Clothes Washer Leak Protection
Required from Certified Counts toward Home Water ScoreUse steel-braided supply hoses, OR install a drain pan under the clothes washer.
-
Plumbing Leak & Pressure Test
Required from Certified Counts toward Zero Water Capable, Home Water ScorePressure test the plumbing system; no leaks permitted. Documented via the LEED-format Water Pressure and Leak Verification Report.
-
Showerhead Flow Rate
Required from Certified Stepped · 4 tiers Counts toward Zero Water Capable, Home Water ScoreAverage measured flow rate of all showerheads in the home. Alternative pathway: meet a Home Water Score threshold.
-
Tank Water Heater Drain Pan
Required from CertifiedInstall a drain pan under any tank water heater located in or above conditioned living space.
-
Toilet Flush Volume
Required from Certified Stepped · 4 tiers Counts toward Zero Water Capable, Home Water ScoreAverage flush volume across all toilets in the home.
-
Cold-Water Pipe Insulation
Required from Gold Counts toward Zero Water CapableInsulate cold-water pipes, or keep them out of unconditioned space.
-
On-Demand Well-Water Softener
Required from GoldWhere well water is the supply, use an on-demand softener.
-
Tap Water Filtration
Required from Gold Counts toward Zero Water CapableInstall tap-water filtration appropriate to local water-quality conditions.
-
Advanced Hot Water Delivery Test
Required from Platinum Counts toward Home Water ScoreHot-water delivery passes the advanced test: ≤ 0.6 gallons before delivery and +10°F temperature rise.
-
Water Leak Detection & Real-Time Metering
Required from Platinum Counts toward Zero Water Capable, Resilience, Home Water ScoreReal-time water leak detection and metering system installed.
Pillar 4
Moisture & Structural Integrity (7)
-
Functional Gutter System
Required from Certified Counts toward Nature-friendly, Storm Water ControlGutters drain water well away from the foundation — OR site has well-draining sandy soils verified per USDA classification.
-
Moisture & Wall Water Leak Assessment
Required from Certified Counts toward Nature-friendly, Storm Water ControlInspect roof condition, flashing, gutters, siding, ground slope, basement moisture (meter), and visible mold/mildew. Repair findings.
-
Certified Shower/Tub Surrounds
Required from SilverNew shower/tub surrounds use ASTM D3273-certified wallboard, certified coating, or drywall-free construction.
-
Moisture-Resistant Flooring in Wet Areas
Required from SilverBathrooms, kitchens, main entryways, and laundry rooms use moisture-resistant flooring.
-
No New Ducts Panned in Joists
Required from Silver New construction onlyNo newly installed ducts are panned in floor joists — they must be fully ducted to prevent unintended air paths.
-
Site Grading or French Drains
Required from Silver New construction only Counts toward Nature-friendly, Storm Water ControlGrading slopes away from the home — or french drains are installed (new construction).
-
All Ducts Fully Ducted
Required from PlatinumAll HVAC ducts are fully ducted — none panned in joists.
Pillar 5
Materials & Environmental Impact (8)
-
Asbestos Mitigation
Required from Certified Existing buildings only Counts toward Sustainable MaterialsMitigate any asbestos found, or document that none is present.
-
Embodied Carbon Reduction
Required from Certified New construction only Stepped · 4 tiers Counts toward GHI Zero Carbon Certified, Foam-free, Sustainable MaterialsReduction in upfront embodied carbon below the 154 kg CO₂e/m² baseline. Approved tools: Beam Estimator, EC3, PHPP (PH Ribbon). Alternative pathways available at Silver (no concrete, RECs, solar offset, small home).
-
Knob-and-Tube Wiring Removed
Required from Certified Existing buildings only Counts toward Reduced Electromagnetic Frequency (EMF)No knob-and-tube wiring remains active in the home.
-
Lead Paint Assessment (Pre-1978 Homes)
Required from Certified Existing buildings only Counts toward Sustainable MaterialsReview and resolve any potential lead-paint issues. Document via the Lead Abatement acknowledgement template.
-
Building Maintenance Instructions
Required from Silver Counts toward Accessibility, ResilienceCreate written instructions documenting how to maintain the building, equipment, and finishes.
-
Homeowner / Tenant Training
Required from Silver Counts toward Accessibility, ResilienceTrain the homeowner or tenant on how to operate and maintain the building.
-
Certified Wood (No Tropical Species)
Required from Gold New construction only Counts toward Sustainable MaterialsNew wood products are FSC or SFI certified. No tropical wood.
-
Floorscore or Green Label Plus Carpet
Required from Platinum New construction only Counts toward Sustainable MaterialsAny new carpet is Floorscore or Green Label Plus certified.
No requirements match the current filters.