Accessibility
Universal design features — zero-step entries, wider doorways, accessible bathrooms — supporting aging in place.
Description
The Accessibility badge recognizes homes designed under universal-design principles — features that allow the home to be used by occupants of any age and ability, and that defer the typical aging-in-place renovation by decades. The badge sits in the Materials & Place pillar because the decisions are mostly about layout, hardware, and durable finishes rather than mechanical systems.
Two compliance paths are recognized: the "Essential" path (visitability + minimum universal-design baseline, suitable for most single-family homes) and the "Full" path (full type-A or type-B accessible unit per ANSI A117.1, suitable for projects where aging-in-place or wheelchair use is the explicit design intent). Achieving either path earns the badge.
Required standard requirements
To earn this badge, the project must meet all of the following existing GreenStar requirements:
Additional badge criteria
Beyond the required standard requirements above, the project must also satisfy:
Essential path — visitability + universal-design baseline
- 01.
At least one zero-step entrance to the main floor from the driveway/sidewalk, no curbs or thresholds > 1/2 inch.
- 02.
All doorways on the main floor at least 32 inches clear (36 inches strongly preferred).
- 03.
At least one full bathroom on the main floor (toilet, sink, and shower/tub) with 60-inch turning radius and reinforced walls (2x blocking) at all toilet and shower locations for future grab-bar installation.
- 04.
Hallway widths at least 36 inches clear; primary corridor at least 42 inches.
- 05.
Lever-style door hardware (not knobs) on all interior doors, and rocker or smart switches in lieu of toggle switches at standard 44-inch mounting height.
- 06.
Kitchen counters with at least one section at adjustable or 34-inch height, and a roll-under or pull-out sink area.
Full path — ANSI A117.1 type-A or type-B unit
- 01.
Project meets all requirements of ANSI A117.1 Section 1003 (Type A) or Section 1004 (Type B) for accessible dwelling units.
- 02.
Roll-in shower with no curb, 60-inch minimum length, and integrated bench seat.
- 03.
Bedroom on the main floor (entry level) with adjacent accessible bathroom.
- 04.
Adjustable-height vanity sinks; reachable controls (motion-activated or front-mounted) on plumbing fixtures.
- 05.
Lever, rocker, or motion-activated hardware throughout.
- 06.
Reinforced walls at all grab-bar locations + grab bars installed (not just blocking) at toilet and shower.
Documentation
- 01.
Marked-up floor plan showing door widths, hallway widths, zero-step entry, bathroom turning radius, and counter heights.
- 02.
For Essential path: photos of zero-step entry, bathroom blocking (pre-drywall photos required), lever hardware, and accessible kitchen counter.
- 03.
For Full path: ANSI A117.1 compliance statement signed by architect, builder, or accessibility consultant.
- 04.
Maintenance plan for accessibility features (e.g. grab-bar inspection cadence, threshold reseal schedule).
Verification by tier
Evidence the project team submits at each certification tier. Cumulative — higher tiers include everything below unless noted otherwise.
-
Certified
Self-attestation- 01.
Owner-signed floor plan annotated with door widths, hallway widths, zero-step entry, and main-floor bathroom layout.
- 02.
Photo of the zero-step entry from the public approach.
- 01.
-
Silver
Documents + photos- 01.
Pre-drywall photos of bathroom blocking at every toilet and shower location.
- 02.
Lever-hardware and rocker/smart-switch spec sheets; kitchen-counter section drawing showing 34-inch accessible run.
- 01.
-
Gold
Third-party test- 01.
On-site inspection by an accessibility consultant or certified universal-design pro at substantial completion.
- 02.
For Full path (ANSI A117.1): compliance statement signed by the architect, builder, or accessibility consultant.
- 01.
-
Platinum
Post-occupancy verification- 01.
Maintenance plan delivered to occupants covering grab-bar inspection cadence and threshold reseal schedule.
- 02.
Annual occupant self-report confirming the accessibility features remain in usable condition.
- 01.